MICRO-PIPETTE

  • Glass-made micro-pipette engineered as a capillary-shaped tool for precision liquid transfer and sample absorption with sub-microliter accuracy.
  • Wide range of capillary diameters from 1μm to 50μm to accommodate different sample viscosities, volumes, and collection requirements.
  • Two distinct tip geometries available: Standard straight capillary for direct access applications and bent (angled) type for confined space and difficult-angle sampling.
  • Enables solid absorption with vacuum absorption tool set or liquid extraction and release with micro-injector systems for complete sample transfer flexibility.
  • Ideal for applications where particle size must be verified larger than the tool’s inner diameter to ensure successful collection without blockage.
  • Provides exceptional precision in liquid handling and sample extraction from confined or delicate environments with minimal dead volume.
  • Compatible with both automated micromanipulator systems and handheld manual operations with heavy-duty MPH variants for maximum versatility.

STRAIGHT TYPE MICRO-PIPETTE APPLICATIONS
  • Solid Particle Absorption - Collect microparticles using vacuum absorption for contamination analysis and particle characterization in semiconductor applications.
  • Liquid Extraction and Dosing - Extract sub-microliter quantities and deliver precise doses to analytical instruments with minimal dead volume and residual contamination.
  • Biological Sample Transfer - Manipulate individual cells and biological fluids at subcellular level for cell biology research and in vitro diagnostics.
  • Microparticulate Suspension Sampling - Selectively sample microparticles from suspensions for particle size distribution analysis and quality control.
  • Viscous Material Transfer - Transfer high-viscosity oils, resins, and pastes with reduced flow resistance using larger-diameter capillaries.
  • Contamination Investigation - Collect contaminant particles from product surfaces for failure analysis and root cause investigation.
BENT TYPE MICRO-PIPETTE APPLICATIONS
  • Confined Space Sampling - Access samples in hard-to-reach areas, narrow slots, and recessed cavities impossible for straight pipettes.
  • Angled Liquid Transfer - Transfer liquids from tight corners and constrained areas requiring lateral approach angles.
  • Under-Surface Collection - Sample from underneath overhanging structures, recessed features, and interior cavities.
  • Restricted Access Tissue Sampling - Extract biological samples from constrained tissue areas and narrow ducts with difficult access.
  • Microelectronics Component Access - Manipulate and sample from tight areas in integrated circuits and circuit board assemblies with precision.
  • Complex Geometry Particle Collection - Collect contaminants from complex 3D structures and irregular geometries in failure analysis investigations.
STRAIGHT TYPE MICRO-PIPETTE - PRODUCT SPECIFICATIONS
Model NumberCapillary TypeInner DiameterOuter DiameterQuantityVolume RangePrimary Application
MP-001Capillary-shaped1μm3-5μm10.1-10 nLSingle-cell sampling, ultra-fine transfers
MP-005Capillary-shaped5μm8-10μm11-100 nLSubcellular operations, nanoliter transfers
MP-010Capillary-shaped10μm15-18μm1010-1000 nLGeneral purpose, precise liquid handling
MP-020Capillary-shaped20μm28-32μm1100-10,000 nLLarger volume transfers, particle collection
MP-050Capillary-shaped50μm70-75μm11-50 μLHigh-volume transfers, batch operations
MPH-001Capillary-shaped (Heavy Duty)1μm3-5μm10.1-10 nLHandheld manual operations
MPH-005Capillary-shaped (Heavy Duty)5μm8-10μm11-100 nLHandheld manual operations
MPH-010Capillary-shaped (Heavy Duty)10μm15-18μm1010-1000 nLHandheld manual operations
MPH-020Capillary-shaped (Heavy Duty)20μm28-32μm1100-10,000 nLHandheld manual operations
MPH-050Capillary-shaped (Heavy Duty)50μm70-75μm11-50 μLHandheld manual operations
BENT TYPE MICRO-PIPETTE - PRODUCT SPECIFICATIONS
Model NumberInner DiameterBend AngleQuantityPrimary Application
MP-005-155μm15°10 pcsAccess to micro-hole, short working distance microscope
MP-005-305μm30°10 pcsAccess to micro-hole, short working distance microscope
MP-005-905μm90°10 pcsFIB thin foil lift-out
MP-010-1510μm15°10 pcsAccess to micro-hole, short working distance microscope
MP-010-3010μm30°10 pcsAccess to micro-hole, short working distance microscope
MP-020-1520μm15°10 pcsAccess to micro-hole, short working distance microscope
MP-020-3020μm30°10 pcsAccess to micro-hole, short working distance microscope
TECHNICAL SPECIFICATIONS (BOTH STRAIGHT & BENT TYPES)
  • Material: High-purity borosilicate glass
  • Inner Diameter Tolerance: ±0.05μm (MP Series), ±0.1μm (MPH Series)
  • Optical Transparency: >99% UV-Visible
  • Surface Finish: Optically polished
  • Dead Volume: <0.1 nL (1μm) to <10 nL (50μm)
  • Operating Temperature: -10°C to +60°C
  • Compatibility: Vacuum absorption tool sets, micro-injector systems, micromanipulators
  • Bent Type Angles Available: 15°, 30°, and 90° for confined-space and angled-access applications
  • Bent Type Packaging: All bent types supplied in 10 pcs packages